VELP's brand new CN 802 element analyzer can determine the total nitrogen and carbon content of the cremated sample in one step. The device is also suitable for receiving solid and liquid samples.
Analysis time: approx. 3-4 minutes. The device can accommodate up to 117 samples in its sample changer, and after starting, it automatically performs the analysis of all samples.
With VELP's cloud-based IT system called ERMES, you can monitor the operation of the device from anywhere and at any time. The measurement data is managed and stored by a dedicated PC software. The PC must be ordered as a separate item.
The system works according to the following international standards: AOAC, DIN, ISO, EN, CEN, EPA, etc.
CN 802 with He carrier gas (the first value) | |
---|---|
Sensors: | Automatically calibrated TCD and NDIR sensor |
Maximum sample weight: | 1 g |
Automatic sample changer capacity: | 4 discs with 30 positions each (supplied with 1 disc) |
Repeatability (RSD): | < 0.5% (for EDTA standards, 9.57%N) Recovery: > 99.5% |
Detection limit for nitrogen: | 0.001 mgN (with Helium), 0.01 mgN (with Argon carrier gas) |
Measuring range for nitrogen: | ppm - 200 mgN |
Detection limit for carbon: | 0.01 mgC |
Measuring range for coal: | ppm -150 mgC |
Connectivity: | to the cloud with WI-FI or LAN |
Required gases:
CN 802 other technical data | |
---|---|
Data connection: | USB; RS232 port, computer control and analysis |
Consumption: | 1,400 W |
Dimensions (W x H x D): | 655x510x410 mm (H: 690 mm with autosampler) |
Weight: | 54 kg |
Delivery includes: device, automatic sample changer with 1 disc, consumables kit for 1,000 measurements, DUMASoft PC software, USB and RS-232 cable. The computer is provided by the user!
The new CN 802 can use two carrier gases. Since Helium is quite expensive, so where the use of Argon is permissible, it will be economical to use this carrier gas.
The detection limit of the device will be 0.01 mg Nitrogen in Argon carrier gas mode. The carrier gas has no effect on the carbon detection limit.
The gas connection of the CN 802 must be designed in such a way that the appropriate gas can be used as needed - by closing one tap and opening another.
Official procedures: | Description: |
---|---|
ISO 10694 | Soil quality - determination of organic and total carbon content using the dry burning method. (Elemental analysis) |
ISO 13878 | Soil quality - Determination of total nitrogen content using the dry burning method. (Elemental analysis) |
ISO 29541 | Solid mineral fuels - Determination of total carbon, hydrogen and nitrogen content - Instrumental method |
ISO 16948 | Solid biofuels - Determination of total carbon, hydrogen and nitrogen content. |
UNI EN 15936 | Sludge, treated biowaste, soil and waste - determination of total organic carbon (TOC) by dry combustion. |
EN 16168 | Sludge, treated biowaste and soil - Determination of total nitrogen by the dry combustion method. |
EN 13654-2 | Soil conditioners and growing media - nitrogen determination Part 2: Dumas method |
ASTM D 7633 | Standard test method for determining the carbon content of carbon black. |
AOAC 993.13 | Total nitrogen content in fertilizers by combustion method. |
The protein/nitrogen determination, which does not require wet chemical sample preparation, works based on the Dumas method
More informationsDevice suitable for determining carbon, hydrogen, nitrogen, sulfur and oxygen.