31.34101
OH-p2
1 x O
pc
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and a heat exchanger for its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device:
1 O-channel with the following measurement ranges
- 0.1 – 200 ppm O
Measuring ranges and sensitivities: in the attached material.
The data refer to a 1 g sample!
Measurement time: within 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and a heat exchanger for its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device:
1 O-channel with the following measurement ranges
- 0.1 – 200 ppm O
Measuring ranges and sensitivities: in the attached material.
The data refer to a 1 g sample!
Measurement time: within 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."
31.34102
OH-p2
2 x H
pc
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device: 2xH channel, manufactured for the following ranges:
- 0.01 – 50 ppm H and 20 – 1,000 ppm H
Measuring ranges and sensitivities: in the attached material. The data refer to a 1 g sample!
Measuring time: 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: Helium, nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device: 2xH channel, manufactured for the following ranges:
- 0.01 – 50 ppm H and 20 – 1,000 ppm H
Measuring ranges and sensitivities: in the attached material. The data refer to a 1 g sample!
Measuring time: 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: Helium, nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."
31.34103
OH-p2
2 × O
pc
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and a heat exchanger for its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device:
2 O-channels, with the following measurement ranges
- 0.1 – 200 ppm O and 10 ppm – 1% O
Measuring ranges and sensitivities: in the attached material.
The data refer to a 1 g sample!
Measurement time: within 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and a heat exchanger for its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device:
2 O-channels, with the following measurement ranges
- 0.1 – 200 ppm O and 10 ppm – 1% O
Measuring ranges and sensitivities: in the attached material.
The data refer to a 1 g sample!
Measurement time: within 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."
31.34104
OH-p2
1 x O + 2 x H
pc
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device: 1xO + 2xH channel, manufactured for the following ranges:
- 0.1 – 200 ppm O,
- 0.01 – 50 ppm H and 20 – 1,000 ppm H
Measuring ranges and sensitivities: in the attached material. The data refer to a 1 g sample!
Measuring time: 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: Helium, nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device: 1xO + 2xH channel, manufactured for the following ranges:
- 0.1 – 200 ppm O,
- 0.01 – 50 ppm H and 20 – 1,000 ppm H
Measuring ranges and sensitivities: in the attached material. The data refer to a 1 g sample!
Measuring time: 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: Helium, nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."
31.34105
OH-p2
2 x O + 2 x H
pc
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and a heat exchanger for its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device:
2 O-channels, with the following measurement ranges
- 0.1 – 200 ppm O and 10 ppm – 1% O
2 H-channels, with the following measurement ranges
- 0.01 – 50 ppm H, and 20 – 1,000 ppm H
Measuring ranges and sensitivities: in the attached material.
The data refer to a 1 g sample!
Measurement time: within 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: Helium, nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."
"Oxygen-Hydrogen determination device equipped with a computer-controlled, pulse-heated furnace and a heat exchanger for its cooling.
Delivered complete with PC, operating / documenting PC software.
The heat exchanger can be fed with tap water (softened).
The range of samples that can be analyzed is: steel, cast iron, alloys, copper, zirconium, titanium, ceramics and other inorganic samples.
The main parameters of the device:
2 O-channels, with the following measurement ranges
- 0.1 – 200 ppm O and 10 ppm – 1% O
2 H-channels, with the following measurement ranges
- 0.01 – 50 ppm H, and 20 – 1,000 ppm H
Measuring ranges and sensitivities: in the attached material.
The data refer to a 1 g sample!
Measurement time: within 2 minutes (normally)
Can be connected to an analytical balance or printer (options)
Necessary gases (depending on the elements to be measured: Helium, nitrogen, compressed air, argon (optional)
- 99.995% pure nitrogen, 2-4 bar
- compressed air, 4-6 bar
Power input: 8.5 KW, 3 phases
Dimensions: 57x77x63 cm (WxHxD)
Weight: approx. 160 kg
Ambient temperature: up to +15...+35°C
The device does not come with consumables, so-called Starter pack!
Consumables must be ordered separately (see below)
An analytical balance is required to measure the sample. The scale is not part of the item, it is provided by the user.
Thus, the measured mass must be entered manually on the computer."