Laboreszköz katalógus
Marketplace 0Cart
EMA 402XL macro elemental analyzer
EMA 402XL macro elemental analyzer

EMA 402XL macro elemental analyzer

Velp Scientifica

Request a price


High temperature elemental analyzer for quantitative CN or CHNS determination of large sample masses. Capable of simultaneously determining carbon, hydrogen, nitrogen and sulfur in a single configuration. Combining innovative crucible technology, advanced detection, intelligent automation and high throughput.

Designed for the analysis of macroorganic samples, it provides high accuracy, robustness and ease of use for a wide range of matrices including soil, fertilizers, biomass, wastes, polymers, petrochemical products, fuels, coal and coke.

The innovative crucible technology enables the direct analysis of extra large solid or liquid samples, up to 3 grams, which is ideal for the determination of CHNS in heterogeneous samples. Compared to conventional devices with tin foils or capsules, the reusable ceramic crucibles significantly simplify sample preparation. The integrated 100-position electronic autosampler enables continuous, unattended analysis and supports non-sequential operation, allowing urgent samples to be prioritized. All analytical phases, from sample loading to crucible disposal, are performed automatically. The samples are transferred from the autosampler by a mechanical arm and fed into the analyzer via a dedicated vertical system. After analysis, the ash remains in the ceramic crucible and is removed with it.

A dynamic, reagent-free vertical furnace that reaches temperatures up to 1350 °C, ensuring complete oxidation of complex macro samples. Carbon, hydrogen and sulfur are measured using an NDIR detector, while nitrogen is measured using a thermal conductivity detector (TCD). The combination of high combustion temperature, optimized gas flow and dual detection technology ensures accurate and repeatable results for CHNS analysis in accordance with ISO and ASTM standards. Monitoring of oxygen consumption during combustion also allows the determination of the total oxygen demand (TOD), supporting the estimation of the calorific value of the sample.

It combines low operating costs with a reagent-free combustion process, ensuring reliable analysis and minimizing laboratory costs. Its robust design extends the life of key components, including the reducing tube, while front access simplifies routine maintenance, helping to reduce downtime. Operation with helium or argon as carrier gas provides flexibility without hardware modifications.

The instrument is managed by EMASoft XL™ software, which provides intuitive control over all analytical steps, from method setup to results visualization. Detectors provide real-time visibility of analytical signals and system performance, while automatic leak checks and system diagnostics ensure consistent reliability over time. Adaptive combustion control automatically adjusts analytical conditions to sample behavior, ensuring complete and reproducible combustion.

Velp Ermes connectivity provides secure cloud-based access, data sharing, and full traceability from any device. Users can remotely monitor results, manage analyses, and schedule maintenance, while maintaining full operational control.

Technical Data EMA 402XL
Operating modes: CHNS, CHN, CNS, CN, TOD
Analysis time: 15 min (CHNS version)
Combustion temperature: Up to 1350 °C
Sample weight: Up to 3 g
Sample feeding: 100-position autosampler with ceramic crucibles
Ash removal: Automatic
Detector: N = TCD (Thermal Conductivity Detector)
CHS = IR (Non-Dispersive Infrared Detectors)
Detection ranges: C: up to 150 mg abs. (or 100 %)
H: up to 10 mg abs. (or 100 %)
N: up to 100 mg abs. (or 100 %)
S: up to 5 mg abs. (or 100 %)
Gases: Carrier Gas: Helium or Argon (grade 4.5)
Combustion gas: Oxygen (grade 4.5)
Connectivity: Ermes Cloud Platform via Wi-Fi or LAN connected to a PC
Dimensions (WxHxD): 980 x 1220 x 490 mm
Weight: 120 kg

picture
code
Type
net price
amount
in stock
331.F30800110
CHNS
Request a price
pc

High-temperature elemental analyzer for the quantitative determination of CHNS content in large sample masses. It combines innovative crucible technology, advanced detection, intelligent automation and high sample throughput. Integrated with a 100-position automatic sample changer for sequential and non-sequential runs. The EMA 402XL uses reusable ceramic crucibles to directly analyze solid and liquid samples weighing up to 3 grams. Automatic ash removal supports continuous, 24-hour operation. Technical data: Measuring modes:CHNS, CHN, CNS, CN, TOD Combustion temperature:Up to 1350 °C Analysis time:15 min (CHNS version) Sample weight:Up to 3 g Sample feeding:Reusable ceramic crucibles Ash removal:Automatic Autosampler:100 positions Detection ranges: C: up to 150 mg abs. (or 100 %) H: up to 10 mg abs. (or 100 %) N: up to 100 mg abs. (or 100 %) S: up to 5 mg abs. (or 100 %) Detectors: N = TCD (thermal conduction detector) CHS = IR (non-dispersive infrared detectors) Gases: Carrier gas: Helium or argon (grade 4.5) Fuel gas: Oxygen (grade 4.5) Connection:Ermes Cloud Platform via Wi-Fi or LAN to PC Dimensions (W x H x D):980 x 1220 x 490 mm Weight:120 kg

High-temperature elemental analyzer for the quantitative determination of CHNS content in large sample masses. It combines innovative crucible technology, advanced detection, intelligent automation and high sample throughput. Integrated with a 100-position automatic sample changer for sequential and non-sequential runs. The EMA 402XL uses reusable ceramic crucibles to directly analyze solid and liquid samples weighing up to 3 grams. Automatic ash removal supports continuous, 24-hour operation. Technical data: Measuring modes:CHNS, CHN, CNS, CN, TOD Combustion temperature:Up to 1350 °C Analysis time:15 min (CHNS version) Sample weight:Up to 3 g Sample feeding:Reusable ceramic crucibles Ash removal:Automatic Autosampler:100 positions Detection ranges: C: up to 150 mg abs. (or 100 %) H: up to 10 mg abs. (or 100 %) N: up to 100 mg abs. (or 100 %) S: up to 5 mg abs. (or 100 %) Detectors: N = TCD (thermal conduction detector) CHS = IR (non-dispersive infrared detectors) Gases: Carrier gas: Helium or argon (grade 4.5) Fuel gas: Oxygen (grade 4.5) Connection:Ermes Cloud Platform via Wi-Fi or LAN to PC Dimensions (W x H x D):980 x 1220 x 490 mm Weight:120 kg

331.F30800120
CN
Request a price
pc

High-temperature elemental analyzer for quantitative determination of CN content in large sample masses. It combines innovative crucible technology, advanced detection, intelligent automation and high sample throughput. Integrated 100-position automatic sample changer for sequential and non-sequential runs. The EMA 402XL uses reusable ceramic crucibles to directly analyze solid and liquid samples weighing up to 3 grams. Automatic ash removal supports continuous, 24-hour operation. Technical data: Measuring modes:CN, TOD Combustion temperature:Up to 1350 °C Analysis time:15 min (CHNS version) Sample weight:Up to 3 g Sample feeding:Reusable ceramic crucibles Deashing:Automatic Autosampler:100 positions Detection ranges: C: up to 150 mg abs. (or 100 %) N: up to 100 mg abs. (or 100 %) Detectors: N = TCD (thermal conduction detector) C = IR (non-dispersive infrared detectors) Gas: Carrier gas: Helium or argon (grade 4.5) Fuel gas: Oxygen (grade 4.5) Connection:Ermes Cloud Platform via Wi-Fi or LAN to PC Dimensions (W x H x D):980 x 1220 x 490 mm Weight:120 kg

High-temperature elemental analyzer for quantitative determination of CN content in large sample masses. It combines innovative crucible technology, advanced detection, intelligent automation and high sample throughput. Integrated 100-position automatic sample changer for sequential and non-sequential runs. The EMA 402XL uses reusable ceramic crucibles to directly analyze solid and liquid samples weighing up to 3 grams. Automatic ash removal supports continuous, 24-hour operation. Technical data: Measuring modes:CN, TOD Combustion temperature:Up to 1350 °C Analysis time:15 min (CHNS version) Sample weight:Up to 3 g Sample feeding:Reusable ceramic crucibles Deashing:Automatic Autosampler:100 positions Detection ranges: C: up to 150 mg abs. (or 100 %) N: up to 100 mg abs. (or 100 %) Detectors: N = TCD (thermal conduction detector) C = IR (non-dispersive infrared detectors) Gas: Carrier gas: Helium or argon (grade 4.5) Fuel gas: Oxygen (grade 4.5) Connection:Ermes Cloud Platform via Wi-Fi or LAN to PC Dimensions (W x H x D):980 x 1220 x 490 mm Weight:120 kg

related products

EMA 502 microelement analyzer
EMA 502 microelement analyzer

Device suitable for determining carbon, hydrogen, nitrogen, sulfur and oxygen.

More informations
Request a price Quotation
Elementrac CN-r type carbon-nitrogen-protein analyzer
Elementrac CN-r type carbon-nitrogen-protein analyzer

Results in less than 3 minutes, based on the Dumas method.

More informations
Request a price Quotation
ELTRA ELEMENTRAC CHS-r carbon, hydrogen and sulfur analyzer
Request a price Quotation
IKA Rotavisc viscometers
Velp automatic extractor