Laboreszköz katalógus
Marketplace 0Cart
Hanna Hi 5321 pH, TDS meter
Hanna Hi 5321 pH, TDS meter
HI 5321 back panel, connections
HI 5321 back panel, connections
Hanna Hi 5321 pH, TDS meter
HI 5321 back panel, connections

HI 5321 Laboratory EC/ TDS/ resistance and salinity meter

Hanna Instruments

Request a price


Tabletop instrument capable of measuring conductivity (EC), resistance and total dissolved salts (TDS).
Large LCD display, computer connection via USB port.
Measurement methods: simple (basic) with or without GLP data, real-time graph representation, data recording mode.
Calibration: In the case of conductivity, one- or four-point, automatic or individual calibration is possible based on standard and individual values.
Single-point salinity calibration (%). Temperature compensation: Automatic, between -20.0 and 120.0 °C.
GLP (Good Laboratory Practice) data is available at the click of a button. The instrument stores the date and time of the calibration, the buffers used, and the offset and slop value of the electrode.
A maximum of 50,000 data can be saved per data group, and can be copied to the computer using a USB cable and the HI92000 software (not included).
Adjustable sampling interval.
Four-Ring Conductivity Probe: The HI76312 four-ring probe has a built-in temperature sensor. The four rings are made of platinum, while the body of the probe is PEI plastic, which is resistant to most chemicals.
During the conductivity measurement, the following parameters can be set individually: temperature compensation coefficient, reference temperature, compensation mode, cell constant and TDS conversion factor.

Table conductivity (EC) / TDS meter technical data:

Specifications: Conductivity (EC) Temperature TDS
Measuring range: 0.01 μS/cm  - 1000 mS/cm, in 6 ranges -20 – +120 °C 000 – 999.9 ppm and 1.000 - 400.0 ppt
 Resolution:  0.01 μS – 1 mS  0.1 °C  0.001 ppm
Accuracy:

±1% of the measured value (±0.01 µS/cm)

±0.2 °C  ±1 of a measured value
Temperature compensation: automatic (ATC), between -20 and 120 °C
Calibration: 4 point
Data download: USB, optional with (HI92000) PC software
Data collecting: 50,000 value
GLP: The instrument stores the date and time of the calibration, the buffers used, and the offset and slop value of the electrode
Display: Color LCD, + touch buttons
Dimensions: 231 x 94 x 160 mm
Weight: 1.0 kg

picture
code
Name
net price
amount
in stock
309.HI5321
HI 5321 Laboratory EC meter
Request a price
pc

"bench-top instrument capable of measuring conductivity (EC), resistivity and total dissolved salt (TDS). Large LCD display, computer connection via USB port Measurement methods: simple (basic) with or without GLP data, real-time graph representation, data recording mode. Calibration: In the case of conductivity, one or four-point, automatic or individual calibration is possible based on standard and individual values. Single-point salinity calibration (%). Temperature compensation: Automatic, between -20.0 and 120.0 °C. GLP (Good Laboratory Practice) data is available at the click of a button. The instrument stores the date and time of the calibration, the buffers used, and the offset and slop value of the electrode. per data group max. 50,000 data can be saved and copied to the computer using a USB cable and the HI92000 software (not included). Adjustable sampling interval. Four-Ring Conductivity Probe: The HI76312 four-ring probe has a built-in temperature sensor. The four rings are made of platinum, while the body of the probe is PEI plastic, which is resistant to most chemicals. During the conductivity measurement, the following parameters can be set individually: temperature compensation coefficient, reference temperature, compensation mode, cell constant and TDS conversion factor. Measuring range: EC value: 0.000-9.999 ?S/cm, 10.00-99.99 ?S/cm, 100.0-999.9 ?S/cm 1.000-9.999 mS/cm, 10.00-99.99 mS/cm, 100.0-1000.0 mS/cm TDS value: 0.000-9.999 ppm, 10.00-99.99 ppm, 100.0-999.9 ppm 1,000-9,999 ppt, 10.00-99.99 ppt, 100.0-400.0 ppt Temperature: between -20.0 and 120.0 °C, between 253.15 and 393.15 K Accuracy: EC value: ±1% of the measured value (±0.01 ?S/cm) TDS value: ±1% of the measured value Temperature: ±0.2 °C, ±0.2K Dimensions: 231mm x 94mm x 160mm Weight: 1.0 kg Accessories: EC probe, electrode holder, mains adapter and instructions for use"

"bench-top instrument capable of measuring conductivity (EC), resistivity and total dissolved salt (TDS). Large LCD display, computer connection via USB port Measurement methods: simple (basic) with or without GLP data, real-time graph representation, data recording mode. Calibration: In the case of conductivity, one or four-point, automatic or individual calibration is possible based on standard and individual values. Single-point salinity calibration (%). Temperature compensation: Automatic, between -20.0 and 120.0 °C. GLP (Good Laboratory Practice) data is available at the click of a button. The instrument stores the date and time of the calibration, the buffers used, and the offset and slop value of the electrode. per data group max. 50,000 data can be saved and copied to the computer using a USB cable and the HI92000 software (not included). Adjustable sampling interval. Four-Ring Conductivity Probe: The HI76312 four-ring probe has a built-in temperature sensor. The four rings are made of platinum, while the body of the probe is PEI plastic, which is resistant to most chemicals. During the conductivity measurement, the following parameters can be set individually: temperature compensation coefficient, reference temperature, compensation mode, cell constant and TDS conversion factor. Measuring range: EC value: 0.000-9.999 ?S/cm, 10.00-99.99 ?S/cm, 100.0-999.9 ?S/cm 1.000-9.999 mS/cm, 10.00-99.99 mS/cm, 100.0-1000.0 mS/cm TDS value: 0.000-9.999 ppm, 10.00-99.99 ppm, 100.0-999.9 ppm 1,000-9,999 ppt, 10.00-99.99 ppt, 100.0-400.0 ppt Temperature: between -20.0 and 120.0 °C, between 253.15 and 393.15 K Accuracy: EC value: ±1% of the measured value (±0.01 ?S/cm) TDS value: ±1% of the measured value Temperature: ±0.2 °C, ±0.2K Dimensions: 231mm x 94mm x 160mm Weight: 1.0 kg Accessories: EC probe, electrode holder, mains adapter and instructions for use"